AI training clusters, GPU-packed private clouds, and edge workloads are pushing today’s data centers to their thermal limits. These modern deployments can generate five to ten times more heat than legacy infrastructure, and analysts expect average rack densities to double again within the next three years. At HostDime, we saw this coming. That’s why we’ve standardized on Trane’s enterprise-grade data center cooling solutions across all of our global facilities, delivering consistent, energy-efficient performance from Orlando to Mexico, Colombia, and Brazil.
Our upcoming Orlando headquarters, codename SuperNova, sets a new standard for next-generation cooling and is designed to support the compute-intensive demands of AI/ML/HPC workloads for years to come.
Why Trane Anchors the HostDime Platform
Advantage | What it means for your business |
---|---|
Oil-free, variable-speed centrifugal compressors | Lower power draw, whisper-quiet 72 dB operation, minimal wear and tear. |
High-ambient design up to 125 °F | Reliable uptime in Florida summers, tropical Brazil, or high-altitude Colombia. |
Same hardware across four countries | Predictable spares, uniform SLAs, and seamless multi-site expansion. |
Native BACnet IP telemetry | Real-time temperature, kW, and alarms in HostDime DCIM and your BMS. |

Inside SuperNova: Future-Ready, Florida-Tough
SuperNova’s thermal plant is purpose-built for today’s workloads… and tomorrow’s. It features a 660-ton Trane chiller plant, built to deliver unmatched reliability, efficiency, and scale.
Feature | Business Benefit |
---|---|
Three 220-ton ACA200 air-cooled chillers (N+1) | Ensures cooling availability even during maintenance windows |
Dedicated refrigerant circuits per compressor | Isolates faults without disrupting the whole system |
Magnetic bearings | Reduces friction, noise, and mechanical failures |
Variable-speed 910 mm condenser fans & pumps | Adjusts cooling dynamically based on real-time load, reducing PUE |
Touchscreen PLC & setpoint control | Engineers can fine-tune settings without taking systems offline |
Dual power disconnects (UPS + Utility) | Keeps critical components operational during outages or transitions |

These data center cooling solutions deliver scalable support for 30 kW racks today and up to 50 kW air-cooled racks tomorrow and are built to evolve with demand.
Sustainability and Cost Control
At HostDime, high performance doesn’t come at the cost of sustainability or operating expenses.
-
Energy Efficiency: Variable-speed drives and oil-free compressors cut energy use by up to 30% over traditional systems.
-
Water-Free Cooling: Our air-cooled design avoids water waste and the chemicals required in evaporative systems.
-
Smarter Maintenance: Predictive diagnostics monitor vibration and temperature 24/7, alerting our team before small issues become downtime risks.
What Decision-Makers Can Expect
Priority | How HostDime Delivers |
---|---|
OPEX Reduction | More efficient systems, fewer service calls, lower total cost of ownership |
Uptime Assurance | 99.999% uptime featuring N+1 redundancy and failover power |
Sustainability & ESG | Precise energy usage metrics and a low-water footprint for green reporting |
Growth-Ready Infrastructure | SuperNova is piped and power-ready for direct-to-chip liquid cooling, giving you a seamless path to 100 kW+ racks without retrofits |
Ready to See It for Yourself?
SuperNova isn’t just HostDime’s newest facility, it’s your launchpad for high-density, AI-ready infrastructure in a region built to scale. For prospective clients, reach out today to schedule a firsthand look at SuperNova.